Health & Saf. Code, § 9635

Verbatim from the official edition

Text — As published in the Legislative Counsel's database, tables dated October 18, 2026 (pubinfo_2025.zip)

(a) All individual crypt openings shall be sealed with a solid panel of precast concrete, not less than 1 1/2 inches thick, fiber reinforced cement board not less than 7/16 inch thick, or other incombustible material that meets all of the following requirements:

(1) A minimum density of 80 pounds per cubic foot.

(2) A minimum modulus of rupture of 270 pounds per square inch.

(3) A minimum compressive strength of 2500 pounds per square inch.

(4) A rating that conforms to Underwriters Laboratories fire hazard class 1.

(b) All panels shall be securely set in with a high quality, nonflammable, resilient, and nonhardening urethane, silicone base, or other appropriate sealant for permanent sealing after interment is made in the crypt. Seal panels shall be set independent of crypt fronts.

Notes and commentary — not statutory text

History

Amended by Stats. 1993, Ch. 350, Sec. 16. Effective January 1, 1994.

Source of truth

Edition
As published in the Legislative Counsel's database, tables dated October 18, 2026 (pubinfo_2025.zip)
Official file
https://leginfo.legislature.ca.gov/faces/codes_displaySection.xhtml?lawCode=HSC&sectionNum=9635.
Text hash
sha256 034c990f8f8450ceb16b108eb0a4c40197ce1aa7e454d789e8ee2af4df29582e
Composed by
compose_ca.py 2026-10-22: the Legislative Counsel's CAML content files read by a tokenizer (caml_readers.reader_a); an independent xml.etree reading (caml_readers.reader_b) agrees on every section
  • printed fractions are shown as 1/4

Procedural information only. Not legal advice and not a substitute for the advice of an attorney. Confirm the current text with the official publisher before relying on it.