Multiple Dwelling Law § 178 · Title 1. Light and Air
Lighting and ventilation of stairs
Text — Law content up to date as of August 28, 2026, as published by the New York State Senate (Open Legislation)
§ 178. Lighting and ventilation of stairs. Where the stair and public halls are not provided on each story with windows opening to a street, yard or court, a skylight equipped with ridge ventilators having an opening of forty square inches or more shall be provided in the roof over the stair, except as otherwise provided in paragraph g of subdivision three of section one hundred seventy-one. The glazed roof of such skylight shall not be less in area than nine square feet nor less than two feet in its least dimension, provided the ventilating and glass areas in such skylight are not less than herein required; except that in dwellings converted before April eighteenth, nineteen hundred twenty-nine, where a skylight smaller than such prescribed dimensions was in existence on such date, no structural change shall be required, but a ventilating skylight fitting the existing skylight opening in the roof beams shall be deemed sufficient.
Source of truth
- Edition
- Law content up to date as of August 28, 2026, as published by the New York State Senate (Open Legislation)
- Official file
- https://legislation.nysenate.gov/pdf/laws/MDW178
- Text hash
- sha256 8bc3578fb8ed8f7d485ee5ef56773ac9fc63ba8ba505e36061fd7407614010e1
- Composed by
- gen_ny_statutes.py 2026-11-10: the Senate's Open Legislation law tree (GET /api/3/laws/<ID>?full=true) read in document order; the Senate's PDF of the whole law (GET /pdf/laws/<ID>?full=true), read with PDFium, prints the same words in the same order
Procedural information only. Not legal advice and not a substitute for the advice of an attorney. Confirm the current text with the official publisher before relying on it.