§ 28. Stairs and entrance halls. In every such dwelling three stories or more in height the wood wainscoting and other combustible materials on the wall and ceiling surfaces in all halls shall be removed and replaced with incombustible or other fire-resistive materials. In lieu of such removal, a sprinkler system may be installed in such halls or such wainscoting and the combustible surfaces may be treated or covered in a manner satisfactory to the department with a surface fire-retardant approved by the department. In such a dwelling, however, any entrance door and every door opening into any entrance hall, stair hall, or other public hall connected therewith, shall be self-closing. Every interior sash, or opening other than a door, in the walls or partitions of such halls and every window therein not opening to the outer air shall be sealed with fire-resistive materials.

Source of truth

Edition
Law content up to date as of May 1, 2026, as published by the New York State Senate (Open Legislation)
Official file
https://legislation.nysenate.gov/pdf/laws/MRE28
Text hash
sha256 baf1aa9a3e841e0a9862eeaa6163ea06ec81e9923f5b2d3545ead6e64b51ad11
Composed by
gen_ny_statutes.py 2026-11-10: the Senate's Open Legislation law tree (GET /api/3/laws/<ID>?full=true) read in document order; the Senate's PDF of the whole law (GET /pdf/laws/<ID>?full=true), read with PDFium, prints the same words in the same order

Procedural information only. Not legal advice and not a substitute for the advice of an attorney. Confirm the current text with the official publisher before relying on it.